ÒÑÇÚíæä ÈáÇ ÍÏæÏ:: ÇáãíÇå# ÇáãÛäÇØíÓíÉ# ÊÃËíÑ ãÌÇá ßåÑæãÛäÇØíÓí# ÊÚãá Úáì #ÇÒÇáå ÇáÊÑÓíÈÇÊ #Úáí# ÇáãÈÇÏáÇÊ ÇáÍÑÇÑíå#

ÇáãíÇå# ÇáãÛäÇØíÓíÉ# ÊÃËíÑ ãÌÇá ßåÑæãÛäÇØíÓí# ÊÚãá Úáì #ÇÒÇáå ÇáÊÑÓíÈÇÊ #Úáí# ÇáãÈÇÏáÇÊ ÇáÍÑÇÑíå#

Magnetic Water Treatment Research Papers:
7. Effect of magnetic technology in scale (7.1 - 7.39).

● 7.10. Title of Research: 
Influence of a modulated electromagnetic field
 on fouling in a double-pipe heat exchanger

- ÊÃËíÑ ãÌÇá ßåÑæãÛäÇØíÓí ãÚÏá Úáì ÇáÞÇÐæÑÇÊ Ýí ãÈÇÏá ÍÑÇÑí ãÒÏæÌ ÇáÃäÈæÈ.

● Researchers: 
Abdullah Shahryari 
 and  Mahmood Pakshir
Department 
of Materials Science 
and Engineering, 
Shiraz University, 
Shiraz, Iran.

● Publisher: Journal of materials 
processing technology, 
203 (2008) 389–395.

-

 æåì ãÌáÉ ÚáãíÉ ÏæáíÉ ãÊÎÕÕÉ æãÊæÇÌÏÉ Ýì
 ãæÞÚ ÓßæÈÓ ãäР
ÚÇã 1990 ÍÊì 
2021 æÍÇÕáÉ Úáì:
CiteScore Tracker in 2020 year = 8.9

- ÃíÖÇð åÐå ÇáãÌáÉ ãÊæÇÌÏÉ
 Ýì ãæÞÚ Web of Science ãäÐ ÚÇã 1990 ÍÊì ÇáÃä
 æåì ÍÇÕáÉ Úáì:
Impact Factor 
in 2020 Year 
= 4.669

● Research Link: https://www.sciencedirect.com/
science/
article/
pii/
S0924013607009727

● Abstract: 
In this study, 
the effect of a modulated electromagnetic field (MEF) 
on fouling in a double-pipe heat exchanger (DPHE) 
has been investigated. 
A double-loop-configuration consisting 
of cooling and heating water cycles was used 
for the experiments. 
The quality of heat transfer 
in the DPHE was studied via
 in situ monitoring of the fouling resistance.
 Moreover, 
the influence of cooling water linear velocity,
 on the MEF treatment efficiency has also been investigated. 
In this regard, 
the water flow velocities of 0.5,
 0.8 and 1.3ms−1 were selected.
 Results show
 that the application of the MEF on the cooling water
 flowing at 0.5 ms−1 velocity, 
decreased 
the fouling resistance 
in the heat exchanger
 by 76.3% compared to the blank (untreated) test.
 However,
 increasing the water velocity resulted in
 a decrease in the MEF efficiency, 
where 64.3% and 57.8% drop in fouling resistance of the DPHE was 
recorded
 for 0.8 and 1.3 ms−1 water velocities,
 respectively.
 On the other hand, 
the water ionic calcium
 (Ca+2)
 measurements showed 
a significant decrease in the cooling water 
calcium as a result of the MEF treatment.
 Finally,
 the MEF design parameters along with the responsible mechanism for the observed results
 have been discussed.

● ãáÎÕ ÇáÈÍË:
- Ýí åÐå ÇáÏÑÇÓÉ ¡
 Êã ÇáÊÍÞíÞ Ýí ÊÃËíÑ ÇáãÌÇá ÇáßåÑæãÛäÇØíÓí ÇáãÚÏá 
O(MEF) Úáì ÇáÞÇÐæÑÇÊ Ýí ãÈÇÏá ÍÑÇÑí ãÒÏæÌ ÇáÃäÈæÈì 
(DPHE) .. Êã ÇÓÊÎÏÇã Êßæíä ÇáÍáÞÉ ÇáãÒÏæÌÉ Çáãßæä ãä ÏæÑÇÊ 
ãíÇå ÇáÊÈÑíÏ æÇáÊÓÎíä ááÊÌÇÑÈ. 
ÊãÊ ÏÑÇÓÉ ÌæÏÉ äÞá ÇáÍÑÇÑÉ
 Ýí
 DPHE ãä ÎáÇá ÇáãÑÇÞÈÉ Ýí ÇáãæÞÚ áãÞÇæãÉ ÇáÞÇÐæÑÇÊ. 

- ÚáÇæÉ Úáì Ðáß ¡
 Êã ÃíÖðÇ ÇáÊÍÞÞ ãä ÊÃËíÑ
 ÇáÓÑÚÉ ÇáÎØíÉ áãÇÁ ÇáÊÈÑíÏ
 Úáì ßÝÇÁÉ ãÚÇáÌÉ 
 MEF.

- Ýí åÐÇ ÇáÕÏÏ ¡ 
Êã ÇÎÊíÇÑ ÓÑÚÇÊ ÊÏÝÞ ÇáãíÇå
 0.5 æ 0.8 æ 1.3
 ãááí ËÇäíÉ
 -1. 

ÃÙåÑÊ ÇáäÊÇÆÌ Ãä ÊØÈíÞ
 MEF Úáì ãíÇå ÇáÊÈÑíÏ 
ÇáãÊÏÝÞÉ ÈÓÑÚÉ 0.5 ãááí ËÇäíÉ -1 ¡
 Þáá ãä ãÞÇæãÉ ÇáÞÇÐæÑÇÊ 
KÝí ÇáãÈÇÏá ÇáÍÑÇÑí ÈäÓÈÉ 76.3٪ 
ãÞÇÑäÉ ÈÇÎÊÈÇÑ ÇáÝÑÇÛ
 (ÛíÑ ÇáãÚÇáÌ). 

- æãÚ Ðáß ¡ 
ÃÏÊ ÒíÇÏÉ ÓÑÚÉ ÇáãÇÁ 
Åáì ÇäÎÝÇÖ Ýí ßÝÇÁÉ 
MEF
 ¡ ÍíË Êã ÊÓÌíá ÇäÎÝÇÖ 
ÈäÓÈÉ 64.3٪ æ 57.8٪ Ýí ãÞÇæãÉ 
ÇáÞÇÐæÑÇÊ áÜ 
DPHE 
ÚäÏ 0.8 æ 1.3 ãááí/ ËÇäíÉ  ÓÑÚÇÊ ãÇÁ ¡
 Úáì ÇáÊæÇáí. 

- ãä äÇÍíÉ ÃÎÑì ¡
 ÃÙåÑÊ ÞíÇÓÇÊ ÇáßÇáÓíæã ÇáÃíæäí ÇáãÇÆí (Ca+2) ÇäÎÝÇÖðÇ ßÈíÑðÇ Ýí ÇáßÇáÓíæã Ýí ãÇÁ ÇáÊÈÑíÏ äÊíÌÉ ãÚÇáÌÉ
 MEF
. ÃÎíÑðÇ ¡
 ÊãÊ ãäÇÞÔÉ 
ãÚáãÇÊ ÊÕãíã MEF ÌäÈðÇ Åáì ÌäÈ ãÚ ÇáÂáíÉ ÇáãÓÄæáÉ Úä ÇáäÊÇÆÌ ÇáãáÇÍÙÉ.

���� ������ 03 ������ 2020  ������  07:43 �����

��� ������ 497